Energy and utilitiesSDWAN Lite
Remote monitoring and control of water pumping stations
Pumping stations are scattered across villages, fields and treatment plants, and many pump controllers only speak serial or Modbus. Instaroute 4G routers connect those controllers to a central SCADA system over cellular, so pumps are monitored and switched remotely, and new stations come online without an engineer configuring each router.
By Pradeep Tomar, Founder and CEO. Published , last reviewed .At a glance
- Industry
- Drinking-water supply, water utilities
- Sites
- Remote pumping stations
- Protocols
- Modbus, serial over TCP/UDP
- Routers
- IR11004GS, IR1180DM
How does the network connect?
Site equipment connects to an Instaroute IR11004GS, which carries the traffic over 4G LTE · SIM 1 inside a quantum-safe tunnel to Central SCADA. Nothing on site accepts inbound connections.
What problem does it solve?
Without a link, pumps are started, stopped and checked by hand, and faults are found late.
Any network has to work with the controllers already installed, which often have only a serial port.
Rural drinking-water and irrigation schemes in India spread pumping stations across many villages, each looked after by a local operator and served by whichever mobile network happens to reach it. A small central team may be responsible for dozens of stations, so knowing which one has stopped reporting, and why, has to happen from the office rather than by driving from site to site.
How does Nexapp solve it?
Cellular routers for pumping stations: Modbus and serial controllers connect to central SCADA over 4G, with zero-touch rollout and one console.
Speaks the site's protocols
RS232/RS485 serial ports, a Modbus RTU/ASCII/TCP gateway, DNP3, IEC 60870-5-101/104 and an MQTT publisher, so existing controllers, RTUs and meters connect without replacement.
Cellular links that stay up
Instaroute 4G and 5G routers with dual-SIM arbitration by signal, latency or data usage, so two operators back each other up. IP65 outdoor units mount on a pole or mast where the signal is best.
One console for every site
Instaroute SDWAN Lite 2.0 shows the health, signal and data usage of every router, with zero-touch set-up and canary firmware rollout, for up to 100,000 devices per deployment. Run it Nexapp-hosted in India or self-hosted.
Encrypted end to end
IPsec IKEv2 tunnels on NexappOS with hybrid post-quantum key exchange (ML-KEM, NIST FIPS 203), on by default, back to the control centre.
How is the site secured in the AI era?
Security is a requirement, not an add-on. AI helps attackers find exposed devices and weak access faster than ever, so this design exposes nothing, encrypts every link and checks every person who connects.
Nothing exposed to the internet
The router opens only outbound, encrypted connections. Equipment on site has no public IP and accepts no inbound connections, so automated scanners have nothing to find. Zero trust access
Quantum-safe encryption on every link
Traffic travels in IPsec IKEv2 tunnels with hybrid ML-KEM key exchange, so data captured today cannot be decrypted later. Post-quantum cryptography
Zones, not one flat network
Each group of equipment on site gets its own zone behind the zone firewall, so one compromised device cannot reach the rest. IoT and OT security
Access for people, not networks
Engineers and vendors connect through InstaAccess to the named equipment they support, and every session is logged. SSE and ZTNA
Signed, staged firmware
Instaroute SDWAN Lite 2.0 rolls out post-quantum-signed firmware to a canary group first, with rollback, so a bad update never reaches every site at once. Instaroute SDWAN Lite 2.0
AI that waits for your approval
NexParth AI spots problems and proposes the fix, and nothing changes until a person approves it. NexParth AI
What does the SDWAN Lite dashboard show?
One screen shows the whole fleet: total devices and online rate, WAN links and SIM cards, active alarms, a fleet map, firmware versions, configuration changes, product mix and data usage. Instaroute SDWAN Lite 2.0 manages up to 100,000 routers per deployment, hosted by Nexapp in India or self-hosted.

How is it deployed?
A typical rollout takes 4 steps, and routers configure themselves when they are powered on at site.
Check the controller
Note whether each pump controller has a serial port or Ethernet and which Modbus mode it uses.
Install in the pump panel
Mount the router, connect the controller over RS232/RS485 or Ethernet and power on.
Bridge to SCADA
The Modbus gateway converts between Modbus RTU and TCP; data travels in an encrypted tunnel.
Control remotely
Operators start, stop and check pumps from the central SCADA system.
What does the specification ask for, and how does Nexapp meet it?
These are the requirements buyers and tenders usually set for this application, and the Nexapp capability that meets each one today.
| Requirement | How Nexapp meets it |
|---|---|
| Work with existing serial controllers | RS232/RS485 serial DTU over TCP or UDP |
| Modbus RTU to Modbus TCP | Built-in Modbus RTU/ASCII/TCP gateway |
| No public or static IP on the SIM | Outbound tunnels and an always-on management channel |
| Fast rollout across villages | Zero-touch provisioning and one template for every station |
Which Instaroute router should you use?
For most sites, use the IR11004GS. DIN-rail or wall mount, serial ports, single SIM: sized for a pump panel.
Instaroute IR11004GS 4G router IR11004GS 4G · LTE · 1 SIM WAN LAN IR11004GS
DIN-rail or wall mount, serial ports, single SIM: sized for a pump panel.
- Cellular
- 4G LTE Cat 4 or Cat 6
- SIM slots
- 1
- RS232 / RS485
- RS232 and RS485
- Mounting
- DIN-rail or wall
Instaroute IR1180DM 4G router IR1180DM 4G · LTE · 2 SIM IR1180DM
Dual SIM and GPS for stations where one operator is not enough.
- Cellular
- 4G LTE Cat 4 or Cat 6
- SIM slots
- 2
- RS232 / RS485
- RS232 and RS485
- Mounting
- DIN-rail
Also used: Instaroute SDWAN Lite 2.0
What are the benefits?
- Pumps monitored and controlled from the central SCADA system.
- Existing controllers connect without replacement.
- New pump sites come online zero-touch.
Why choose Nexapp?
- Indian OEM in Pune since 2014, with its own NexappOS and controller
- Class-I local supplier under the PPP-MII Order
- TEC MTCTE certificate 244903206 for nine Instaroute models
- Quantum-safe on every connection: hybrid ML-KEM and ML-DSA
- 24×7 NOC in Pune; hosted in India or self-hosted
- 75,000+ devices deployed for 400+ enterprise and banking customers
Frequently asked questions
Can the router connect a pump controller that only has a serial port?
Yes. The RS232/RS485 port carries serial data over TCP or UDP, and the Modbus gateway translates between Modbus RTU and Modbus TCP.
Which router fits inside a pump panel?
The IR11004GS: single SIM, RS232/RS485, one LAN and one WAN port, DIN-rail or wall mounting and an IP30 enclosure meant for inside the panel. Choose the IR1180DM where the station needs a second operator, and add the outdoor IR1105-ODU-4G where the panel room has poor signal.
Can SCADA send start and stop commands over the 4G link?
Yes. Commands travel from SCADA to the pump controller or PLC over Modbus or serial, and the controller switches the pump. The router carries the commands; it has no inputs or outputs of its own.
How does the control room know a station's link is getting weak?
Each router reports signal quality per SIM, and SDWAN Lite 2.0 raises signal-quality and data-usage alarms by email, webhook or in the console, so a fading station is flagged before it drops off.
Can a panel builder or local contractor install the router?
Yes. The router is registered in advance from its serial number, so the installer only mounts it, inserts the SIM, connects the controller and powers it on. It downloads its configuration by itself.
Read next
Planning a similar deployment?
Tell us your sites, devices and links, and a Nexapp engineer will recommend the routers and design.
Related use cases
Energy and utilities
4G router for substation SCADA and RTU/FRTU backhaulIndustrial 4G routers for substations, RTUs and FRTUs: IEC 60870-5-101/104, DNP3, Modbus, serial DTU and encrypted tunnels to the SCADA control centre.
Energy and utilities
Cellular backhaul for smart meters and data concentrator units4G routers for smart-meter data concentrator units (DCUs) and AMR: serial and Modbus interfaces, MQTT, encrypted tunnels and flat per-device management.
Energy and utilities
Remote monitoring and connectivity for solar plantsOne managed network for inverters, meters, weather stations and cameras across solar farms and rooftop plants, with scoped vendor access and one console.