Industrial and manufacturingSDWAN Lite
Machine monitoring and predictive maintenance connectivity
Predictive maintenance starts with getting data off the machines. Instaroute routers read drives, meters, compressor and DG set controllers and CNC machines over Modbus and RS232/RS485, publish the readings over MQTT to the monitoring or analytics platform you choose, and keep the machine network apart from office IT. Your platform raises the alerts; the router keeps the data flowing over the plant LAN or 4G.
By Pradeep Tomar, Founder and CEO. Published , last reviewed .At a glance
- Industry
- Manufacturing, process plants, facilities
- Machines
- Motors and drives, compressors, DG sets, CNC
- Protocols
- Modbus RTU/ASCII/TCP, RS232/RS485, MQTT
- Routers
- IR1190DMG, IR11004GS
How does the network connect?
Site equipment connects to an Instaroute IR1190DMG, which carries the traffic over Plant LAN or broadband and 4G LTE · backup or primary inside a quantum-safe tunnel to Monitoring / analytics platform and Maintenance team. Nothing on site accepts inbound connections.
What problem does it solve?
Many machines that matter most, such as older compressors, DG sets and CNC machines, expose their data only on a serial port or over Modbus, and sit on separate panels across the plant or at remote sites.
Monitoring platforms expect MQTT or TCP, while plant IT will not let machines onto the office network. Adding a separate converter, modem and firewall to every line adds boxes to buy, power and manage.
When a reading points to a fault, the maintenance team or machine builder needs to look at the controller, which should not mean opening the plant to the internet.
How does Nexapp solve it?
Read Modbus and serial data from motors, compressors, DG sets and CNC machines and publish it over MQTT to your platform, over plant LAN or 4G, apart from IT.
From Modbus and serial to MQTT
The Modbus RTU/ASCII/TCP gateway reads drives, meters and controllers, the serial DTU carries RS232/RS485 devices over TCP or UDP, and the MQTT publisher sends the readings to the platform you choose.
Each system in its own zone
Zone firewalls and VRFs keep the machine network separate from office IT, so machines can send data out without being reachable from office laptops.
Any uplink, including 4G
Use the plant LAN or broadband on any port, with 4G as backup, or 4G alone for a DG set or compressor at a remote site. Dual-SIM models switch operators by signal, latency or data usage.
Vendor access without open ports
Engineers and equipment vendors connect through the InstaAccess client (ZTNA, SSL VPN or IPsec VPN) to only the equipment they support, and every session is logged.
One console for every site
Instaroute SDWAN Lite 2.0 shows the health, signal and data usage of every router, with zero-touch set-up and canary firmware rollout, for up to 100,000 devices per deployment. Run it Nexapp-hosted in India or self-hosted.
How is the site secured in the AI era?
Security is a requirement, not an add-on. AI helps attackers find exposed devices and weak access faster than ever, so this design exposes nothing, encrypts every link and checks every person who connects.
Nothing exposed to the internet
The router opens only outbound, encrypted connections. Equipment on site has no public IP and accepts no inbound connections, so automated scanners have nothing to find. Zero trust access
Quantum-safe encryption on every link
Traffic travels in IPsec IKEv2 tunnels with hybrid ML-KEM key exchange, so data captured today cannot be decrypted later. Post-quantum cryptography
Zones, not one flat network
Each group of equipment on site gets its own zone behind the zone firewall, so one compromised device cannot reach the rest. IoT and OT security
Access for people, not networks
Engineers and vendors connect through InstaAccess to the named equipment they support, and every session is logged. SSE and ZTNA
Signed, staged firmware
Instaroute SDWAN Lite 2.0 rolls out post-quantum-signed firmware to a canary group first, with rollback, so a bad update never reaches every site at once. Instaroute SDWAN Lite 2.0
AI that waits for your approval
NexParth AI spots problems and proposes the fix, and nothing changes until a person approves it. NexParth AI
What does the SDWAN Lite dashboard show?
One screen shows the whole fleet: total devices and online rate, WAN links and SIM cards, active alarms, a fleet map, firmware versions, configuration changes, product mix and data usage. Instaroute SDWAN Lite 2.0 manages up to 100,000 routers per deployment, hosted by Nexapp in India or self-hosted.

How is it deployed?
A typical rollout takes 5 steps, and routers configure themselves when they are powered on at site.
List the machines
Note each machine's controller, protocol (Modbus RTU, Modbus TCP or plain serial) and the readings the platform needs.
Template the gateway
Set the serial and Modbus settings, the MQTT broker and the zone policy once, as a template per machine type.
Install at the machine
Mount the router in the machine panel, connect the controller over RS232/RS485 or Ethernet, and connect the plant LAN or a SIM.
Publish to the platform
Readings flow over MQTT to the monitoring platform, where dashboards and alert rules are set.
Maintain remotely
Gateways are updated from one console, and the machine builder reaches named machines through InstaAccess.
What does the specification ask for, and how does Nexapp meet it?
These are the requirements buyers and tenders usually set for this application, and the Nexapp capability that meets each one today.
| Requirement | How Nexapp meets it |
|---|---|
| Read Modbus and serial controllers | Modbus RTU/ASCII/TCP gateway; RS232/RS485 serial DTU over TCP or UDP |
| Send data to an MQTT platform | MQTT data publisher on the router |
| Machines separated from office IT | Zone firewall and VRF segmentation |
| Uplink at sites without a LAN | 4G LTE Cat 4/6; dual-SIM arbitration on the IR1190DMG; any-port WAN with link backup |
| Remote support for machine builders | InstaAccess client to named machines, every session logged |
| Central configuration and firmware | Zero-touch provisioning and canary firmware rollout with rollback |
Which Instaroute router should you use?
For most sites, use the IR1190DMG. Gigabit DIN-rail router with serial ports and dual SIM for machine panels; no Wi-Fi.
Instaroute IR1190DMG 4G router IR1190DMG 4G · LTE · 2 SIM IR1190DMG
Gigabit DIN-rail router with serial ports and dual SIM for machine panels; no Wi-Fi.
- Cellular
- 4G LTE Cat 4 or Cat 6
- SIM slots
- 2
- RS232 / RS485
- RS232 and RS485
- Mounting
- DIN-rail or wall
Instaroute IR11004GS 4G router IR11004GS 4G · LTE · 1 SIM WAN LAN IR11004GS
Entry-level single-SIM 4G with serial ports for one DG set or compressor at a remote site.
- Cellular
- 4G LTE Cat 4 or Cat 6
- SIM slots
- 1
- RS232 / RS485
- RS232 and RS485
- Mounting
- DIN-rail or wall
Also used: Instaroute SDWAN Lite 2.0 · InstaAccess client (ZTNA, SSL VPN, IPsec VPN)
What are the benefits?
- Existing machines report without replacing their controllers.
- Machine data reaches the platform you choose over MQTT.
- Machine networks stay separate from office IT.
- Remote machines at sites without a LAN report over 4G.
- Machine builders reach named machines only, with every session logged.
- Every gateway is configured and updated from one console.
Why choose Nexapp?
- Indian OEM in Pune since 2014, with its own NexappOS and controller
- Class-I local supplier under the PPP-MII Order
- TEC MTCTE certificate 244903206 for nine Instaroute models
- Quantum-safe on every connection: hybrid ML-KEM and ML-DSA
- 24×7 NOC in Pune; hosted in India or self-hosted
- 75,000+ devices deployed for 400+ enterprise and banking customers
Frequently asked questions
Can the router send Modbus data to an MQTT platform?
Yes. It reads Modbus RTU, ASCII or TCP devices through its Modbus gateway and sends the data to your platform with its MQTT publisher.
Does Nexapp provide the predictive maintenance software?
No. Nexapp provides the connectivity, protocol gateway and security. Analytics, dashboards and alerts run on the monitoring platform you choose.
Can it connect a machine that only has a serial port?
Yes. The RS232/RS485 port carries serial data over TCP or UDP, and the Modbus gateway translates between Modbus RTU and Modbus TCP.
Can we monitor DG sets and compressors at remote sites?
Yes. A 4G router such as the IR11004GS connects the controller over cellular, so no wired link is needed at the site.
Are machines exposed to the office network or the internet?
No. Zone firewalls and VRFs keep the machine network separate, and the router sends data outbound, so nothing on the machine side accepts inbound connections.
Read next
Planning a similar deployment?
Tell us your sites, devices and links, and a Nexapp engineer will recommend the routers and design.
Related use cases
Industrial and manufacturing
Secure remote access to PLCs, HMIs and machinesLet machine builders and engineers reach PLCs and HMIs without opening the plant network: InstaAccess ZTNA, SD-LAN behind the router, logged sessions.
Industrial and manufacturing
Central management and IT/OT segmentation for plant networksSeparate plant OT from office IT with zone firewalls and VRFs on Instaroute routers, link every plant to head office and manage plant networks from one console.
Industrial and manufacturing
Wireless connectivity for machines across the factory floorConnect shop-floor machines and sensors over Wi-Fi: Wi-Fi 6 on IRX100 routers, dedicated access points on request, machine and staff networks kept apart.