TelecomSDWAN Lite

Remote monitoring and management of telecom tower sites

Tower sites are unmanned and spread across large areas, and power systems, batteries, diesel generators and access alarms all need watching. Instaroute routers carry site data to the NOC over a managed cellular link and give the operations team an independent way in to diagnose equipment when the primary link fails.

At a glance

Industry
Telecom infrastructure, tower companies
Sites
Unmanned tower and BTS sites
Devices
Power systems, batteries, DG sets, alarms
Routers
IR11004GD, IR1180DM

How does the network connect?

Site equipment connects to an Instaroute IR11004GD, which carries the traffic over SIM 1 · Operator A and SIM 2 · Operator B inside a quantum-safe tunnel to Operations NOC. Nothing on site accepts inbound connections.

NEXAPP CLOUD PLATFORMInstaroute SDWAN Lite 2.0Dashboard · alarms · zero-touch · firmwareHosted in India or self-hostedManagement · no public IPYour teamREMOTE SITEMOBILE NETWORK · INTERNETCONTROL CENTREPower system andbatteriesDG controllerDoor and alarmsensorsIR11004GDInstaroute · NexappOSSIM 1 · Operator ASIM 2 · Operator BOperator coreOperations NOCIPsec IKEv2 · hybrid ML-KEMQuantum-safe tunnel · outbound only, nothing on site accepts inbound connectionsNEXAPP CLOUD PLATFORMInstaroute SDWAN Lite 2.0Dashboard · alarms · firmwareIndia-hosted or self-hostedREMOTE SITEPower system and batteriesDG controllerDoor and alarm sensorsIR11004GD · InstarouteMOBILE NETWORK · INTERNETSIM 1 · Operator ASIM 2 · Operator BIPsec IKEv2 · hybrid ML-KEMCONTROL CENTREOperations NOC
How it connects: Power system and batteries, DG controller, Door and alarm sensors at the remote site connect to the IR11004GD dual-SIM 4G. Traffic travels over SIM 1 · Operator A and SIM 2 · Operator B inside a quantum-safe tunnel (IPsec IKEv2 · hybrid ML-KEM) to Operations NOC. The router is managed from the Nexapp cloud platform (Instaroute SDWAN Lite 2.0), hosted in India or self-hosted, over an always-on management channel that needs no public IP.

What problem does it solve?

A site visit is expensive, and many faults could be diagnosed remotely if someone could reach the equipment.

When the main link to a site fails, the operations team needs another way in to see what happened.

Tower sites in India lean heavily on batteries and diesel generators to ride through grid outages, so DG run hours, fuel levels, battery health and door alarms matter as much as the radio equipment. Sites are spread across cities, highways and villages, often shared by several tenants, and a problem found a day late can mean a dead battery bank or a site down for every tenant.

How does Nexapp solve it?

Cellular routers for unmanned tower sites: power, battery, DG and alarm data to the NOC, with an independent path in when the primary link fails.

  • Cellular links that stay up

    Instaroute 4G and 5G routers with dual-SIM arbitration by signal, latency or data usage, so two operators back each other up. IP65 outdoor units mount on a pole or mast where the signal is best.

  • Speaks the site's protocols

    RS232/RS485 serial ports, a Modbus RTU/ASCII/TCP gateway, DNP3, IEC 60870-5-101/104 and an MQTT publisher, so existing controllers, RTUs and meters connect without replacement.

  • A second way in

    The router gives the NOC an independent cellular path to site equipment, so a failed primary link can be diagnosed remotely.

  • One console for every site

    Instaroute SDWAN Lite 2.0 shows the health, signal and data usage of every router, with zero-touch set-up and canary firmware rollout, for up to 100,000 devices per deployment. Run it Nexapp-hosted in India or self-hosted.

How is the site secured in the AI era?

Security is a requirement, not an add-on. AI helps attackers find exposed devices and weak access faster than ever, so this design exposes nothing, encrypts every link and checks every person who connects.

  • Nothing exposed to the internet

    The router opens only outbound, encrypted connections. Equipment on site has no public IP and accepts no inbound connections, so automated scanners have nothing to find. Zero trust access

  • Quantum-safe encryption on every link

    Traffic travels in IPsec IKEv2 tunnels with hybrid ML-KEM key exchange, so data captured today cannot be decrypted later. Post-quantum cryptography

  • Zones, not one flat network

    Each group of equipment on site gets its own zone behind the zone firewall, so one compromised device cannot reach the rest. IoT and OT security

  • Access for people, not networks

    Engineers and vendors connect through InstaAccess to the named equipment they support, and every session is logged. SSE and ZTNA

  • Signed, staged firmware

    Instaroute SDWAN Lite 2.0 rolls out post-quantum-signed firmware to a canary group first, with rollback, so a bad update never reaches every site at once. Instaroute SDWAN Lite 2.0

  • AI that waits for your approval

    NexParth AI spots problems and proposes the fix, and nothing changes until a person approves it. NexParth AI

What does the SDWAN Lite dashboard show?

One screen shows the whole fleet: total devices and online rate, WAN links and SIM cards, active alarms, a fleet map, firmware versions, configuration changes, product mix and data usage. Instaroute SDWAN Lite 2.0 manages up to 100,000 routers per deployment, hosted by Nexapp in India or self-hosted.

Instaroute SDWAN Lite 2.0 dashboard with device status, WAN and SIM health, alarms, fleet map, firmware distribution and data usage (sample data)
Instaroute SDWAN Lite 2.0 dashboard, shown with sample data. See SDWAN Lite 2.0

How is it deployed?

A typical rollout takes 4 steps, and routers configure themselves when they are powered on at site.

  1. Connect site controllers

    Power systems, battery monitors, DG controllers and alarms connect over serial or Ethernet.

  2. Add an independent path

    The router's cellular link gives the NOC a way in that does not depend on the site's primary link.

  3. Report to the NOC

    Alarms and power data travel in encrypted tunnels to the operations NOC.

  4. Fix remotely first

    Engineers diagnose many faults from the NOC before sending a field team.

What does the specification ask for, and how does Nexapp meet it?

These are the requirements buyers and tenders usually set for this application, and the Nexapp capability that meets each one today.

Typical requirements: remote monitoring and management of telecom tower sites
RequirementHow Nexapp meets it
Reach the site when the primary link failsIndependent dual-SIM cellular path to site equipment
Serial power and DG controllersRS232/RS485 ports and Modbus gateway
No public IP at each siteOutbound tunnels and an always-on management channel
Fleet-wide firmware and configurationSDWAN Lite 2.0 with canary firmware rollout

Which Instaroute router should you use?

For most sites, use the IR11004GD. Dual SIM and five Ethernet ports for site controllers.

  • Instaroute IR11004GD 4G routerIR11004GD4G · LTE · 2 SIM

    IR11004GD

    Dual SIM and five Ethernet ports for site controllers.

    Cellular
    4G LTE Cat 4 or Cat 6
    SIM slots
    2
    RS232 / RS485
    RS232 and RS485
    Mounting
    Desktop or wall
  • Instaroute IR1180DM 4G routerIR1180DM4G · LTE · 2 SIM

    IR1180DM

    DIN-rail with serial ports and GPS for equipment cabinets.

    Cellular
    4G LTE Cat 4 or Cat 6
    SIM slots
    2
    RS232 / RS485
    RS232 and RS485
    Mounting
    DIN-rail

Also used: Instaroute SDWAN Lite 2.0

What are the benefits?

  • Site alarms and power data reach the NOC over a managed link.
  • Many faults are diagnosed without a site visit.
  • Firmware and configuration are managed centrally for every site.

Why choose Nexapp?

  • Indian OEM in Pune since 2014, with its own NexappOS and controller
  • Class-I local supplier under the PPP-MII Order
  • TEC MTCTE certificate 244903206 for nine Instaroute models
  • Quantum-safe on every connection: hybrid ML-KEM and ML-DSA
  • 24×7 NOC in Pune; hosted in India or self-hosted
  • 75,000+ devices deployed for 400+ enterprise and banking customers

Frequently asked questions

Can the router monitor serial power and DG controllers?

Yes. RS232/RS485 ports and the Modbus gateway connect serial controllers and carry their data to the NOC.

Which router suits a tower site?

The IR11004GD where controllers connect over Ethernet: two SIMs and five ports. The DIN-rail IR1180DM fits equipment cabinets, with two SIMs, RS232/RS485 for serial power and DG controllers, and GPS.

Which operators should the router's SIMs use?

For a truly independent path, choose operators whose service does not depend on the site's own primary backhaul, confirmed by a signal survey. With two SIMs from different operators, the router still has a way in if one network is affected.

Can site alarms reach our existing NOC tools?

Yes. The routers support SNMP v2c/v3, TR-069 and syslog, and SDWAN Lite 2.0 adds alarm webhooks, a documented REST API and syslog export to your SIEM.

How do NOC engineers reach a controller at the site?

They open browser SSH or the router's web UI from the console, or reach the controller behind it through SD-LAN or the InstaAccess client. Router logins can be checked against RADIUS or TACACS+, and remote sessions are logged.

Read next

Planning a similar deployment?

Tell us your sites, devices and links, and a Nexapp engineer will recommend the routers and design.